EX-FLOW Ex-Proof (ATEX Zone-1 Certified) Mass Flow Meters / Controllers for gases
General
EX-FLOW instruments are thermal Mass Flow Meters / Controllers of rugged design and suitable for gas flow application in hazardous areas. The intrinsically safe measuring head is tested according to ATEX 100a Directive 94/9/EC and approved under EC-Type Examination Number: KEMA 01ATEX1172, protection II 2 G Ex ib IIC T4. The housing of the electronics compartment is to IP65 classification. Control valves can either be integrally or separately mounted, to measure and control gas flows (air-equivalent) from:
Lowest range 0,16 ... 8 mln/min Highest range 220 ... 11.000 m3n/h (Mass FlowMeter) 10 ... 500 m3n/h (Mass FlowController)
Flow Control
An EX-FLOW Mass Flow Controller has a control valve with fast and smooth control characteristics. The flow meter and valve should be connected (via separate cables) to a power supply with galvanic isolation / preamplifier / readout system (located in the safe zone) which contains a controller board to complete the control loop. The control valve receives its input from the controller board and immediately responds to any deviation between the output signal from the flow sensor and the setpoint signal.
Bronkhorst High-Tech applies two sorts of coils: Style "XB" = protection II 1 G/D Ex ia IIC T6; intrinsic safe coil; needs safety barrier. Style "XC" = protection II 2 G/D Ex e mb II T4; moulded coil; no safety barrier required.
Power Supply / Readout Systems
To complete the EX-FLOW system, Bronkhorst High-Tech developed a PS/Readout unit, offering the following functions:
- indication
- control
- alarms
- totalization
- safety barrier
- power supply with galvanic isolation
For more information: see Digital PS/Readout Systems
EX-FLOW features
- ATEX approval Cat.2, Zone 1
- Pressure ratings up to 700 bar
- Rugged, weatherproof housing (IP65, dust and waterproof)
- optional: low-ΔP versions up to 4...200 ln/min
Flow capacities (based on air)
Mass Flow Meters |
Ranges |
Type of process connections |
| Series F-110CX |
min. 0,16 ... 8 mln/min max. 0,2 ... 10 mln/min |
Compression type couplings |
| Series F-111BX |
min. 0,2 ... 10 mln/min max. 0,4 ... 20 ln/min |
Compression type couplings |
| Series F-111AX |
min. 0,1 ... 5 ln/min max. 2 ... 100 ln/min |
Compression type couplings |
| Series F-112AX |
min. 0,2 ... 10 ln/min max. 5 ... 250 ln/min |
Compression type couplings |
| Series F-113AX |
min. 2 ... 100 ln/min max. 25 ... 1250 ln/min |
Compression type couplings |
Series F-116AX/BX |
min. 0,4 ... 20 m3n/h max. 10 ... 500 m3n/h |
Compression type couplings |
Series F-106AX/.../GX |
min. 0,4 ... 20 m3n/h max. 220 ... 11000 m3n/h |
"wafer type" for mounting between flanges |
Series F-107AX/.../DX |
min. 0,4 ... 20 m3n/h max. 36 ... 1800 m3n/h |
flanged connection (DIN or ANSI) |
Mass Flow Controllers |
Ranges |
| Series F-200CX 1) |
min. 0,2 ... 10 mln/min max. 0,2 ... 10 mln/min |
| Series F-201CX 1) |
min. 0,22 ... 11 mln/min max. 0,4 ... 20 ln/min |
| Series F-201AX 1) |
min. 0,1 ... 5 ln/min max. 2 ... 100 ln/min |
| Series F-202AX 2) |
min. 0,2 ... 10 ln/min max. 5 ... 250 ln/min |
| Series F-203AX 2) |
min. 2 ... 100 ln/min max. 25 ... 1250 ln/min |
| Series F-206AX/BX 2) |
min. 0,4 ... 20 m3n/h max. 10 ... 500 m3n/h |
Series F-230MX/ F-231MX/F-232MX 3) |
min. 0,2 ... 10 mln/min max. 2 ... 100 ln/min |
1) with small type of valve for normal applications 2) with pilot-operated valve for high flow applications 3) with vary-p-valve for high (differential) pressure applications up to 400 bar
Brochure
For more information see brochure "EX-FLOW mass flow meters/controllers for gases"
|  F-111BX Mass Flow Meter  F-201AX Mass Flow Controller  F-113AX Mass Flow Meter  F-203AX Mass Flow Controller  F-106AX Mass Flow Meter  F-107CX flanged type Mass Flow Meter
|